Microwave-assisted extraction and determination of dicyandiamide residue in infant formula samples by liquid chromatography-tandem mass spectrometry
A simple, precise, accurate, and validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of dicyandiamide residue in infant formula samples. Following microwave-assisted extraction with 5% formic acid and clean-up on a Sep-Pak AC-2 SPE cartridge, samples were separated on a ZIC-HILIC HPLC column (150 × 2.1 mm i.d., 5-µm film thickness; Merck KGaA, Darmstadt, Germany) with 20 mM ammonium acetate solution-acetonitrile as mobile phase at a flow rate of 0.25 mL/min. A linear calibration curve was obtained in the concentration range from 1.0 to 50 ng/mL. Infant formula samples were fortified with dicyandiamide at 3 levels, producing average recovery yields of 83.6 to 95.7%. The limits of detection and quantification of dicyandiamide were 3 and 10 μg/kg, respectively. Due to its simplicity and accuracy, the straightforward method is particularly suitable for routine dicyandiamide detection.
原文://www.sciencedirect.com/science/article/pii/S0022030213006462